Industrial

Educational

Scientific

Engineering questions

Sample problems

Examples gallery

Step-by-step tutorials

Verification examples

Programming examples

Distributive examples

Success stories

Customers

Main >> Applications >> Sample problems

Magnetic Measuring Fixture - QuickField simulation example

This simulation example is prepared by Nils Pahlbäck.

This example illustrates the simulation of a magnetic measuring fixture using QuickField software.

The fixture is designed for quality testing of radially magnetized permanent magnets. A magnetic circuit made of low-coercivity soft iron leads the magnetic flux from the magnet under test through an air gap containing a Hall-effect sensor positioned at the tip of a probe.

Since the magnetic performance of a permanent magnet depends on the magnetic circuit in which it operates, the most representative testing conditions are achieved by reproducing the magnetic environment of the intended application as closely as possible.

The Hall-effect sensor has a very small active sensing area. To ensure high measurement accuracy, repeatability, and sufficient tolerance for variations in probe positioning, the air gap must provide a sufficiently large region with a uniform magnetic flux density and field direction.

The ratio between the cross-sectional area and the length of the air gap is an important design parameter influencing the extent of the region in which the magnetic flux density and field direction remain approximately uniform.

Engineering question

How to design the air gap of a Hall sensor probe so that the measured flux density is insensitive to the probe position?

Answer
Solve the axisymmetric magnetostatic problem of the measuring chamber and plot the flux density along a contour across the sensor area; increase the area-to-length ratio of the air gap until the flux density is almost constant over the zone where the Hall sensor may be located.

More questions →

Typical applications
permanent magnet quality control, radially magnetized ring magnets, Hall sensor probes, magnetic measuring fixtures

Ring magnet quality test probe

Download

Simulation problem

Problem Type
Axisymmetric problem of DC magnetics.

Geometry
Ring magnet quality test probe Axisymmetric model of the measuring chamber: iron flux path, radially magnetized magnet, Hall sensor in the air gap on the axis and two additional iron blocks near the gap. Air Iron Iron Hall sensor N S Additional iron blocks 9.8 mm Ø17.1 mm 1 mm

Given
Radially magnetized permanent magnet: coercive force Hc = 355 kA/m;
The B-H curve for the iron flux path:

Task
The purpose of the simulation is to evaluate and optimize the air-gap geometry to achieve a sufficiently homogeneous magnetic field within the required probe positioning tolerance.

Solution
Properties are assigned to all blocks and the finite element mesh is built. After the problem is solved, a contour for the flux density plot is defined across the sensor area. The curve is plotted in the direction of the arrow on the contour.
The model has two predefined blocks, which can be assigned iron properties. This changes the area of the air gap without redrawing the geometry, so both designs are compared in the same model. The display settings of the field picture can be saved as a view state and recalled when needed.

Results
Flux density in the measuring chamber with the additional iron blocks and flux density along the contour over the Hall sensor.
Flux density in the measuring chamber

In the initial design the flux in the sensor area is inhomogeneous due to field line deviation close to the edge of the air gap. Increasing the diameter of the air gap gives a larger area in the center with a homogeneous flux. When the problem is solved with the additional iron blocks, the flux density is almost constant over the area where the Hall sensor is located.
The ratio of the area to the length of the air gap determines the accuracy of the field direction.