How to Try the Optimization Main Features?

1. Start LabelMover Optimization

There are two main ways to start LabelMover.

You can use Windows Start menu: Start>Programs>Tera Analysis>Tools>QuickField LabelMover>Parametric Analysis with LabelMover.

Or you can start LabelMover from QuickField, as an add-in. For it, choose Tools>Parametric Analysis with LabelMover in QuickField menu. You can also use toolbar button or Ctrl+Alt+M shortcut.

After LabelMover is started you should switch to Optimization analysis using button at the Start page.

2. Specify the Base Problem

Press Base Problem... button. In the file dialog, choose the base problem you would like to optimize.

3. Specifying Optimization Goal

Press the Add Values & Goal... button. Values & Goal definition dialog will appear.

4. Specify Variations

Press the Add Variations... button. Variation definition dialog will appear.

Please see Adding Variations for Optimisation for more information

5. Do Optimization

Now you can start the optimization process:

Tip. Progress bar will appear, indicating how many problems are already generated and solved. If you decide that the best solution found so far is already satisfactory, you can press Cancel button and quit the optimization process at any time.

6. Viewing Results

Results for Optimization are very similar to the results of the Serial analysis. The optimal solution is highlighted with red color for maximum and blue color for minimum.

For more information please see
Optimization Overview
Theoretical Description for Optimization
More LabelMover Features