There are several ways to calculate capacitance using QuickField. The easiest one of them is based on measuring an electric potential produced by a known charge. To get capacitance of a conductor, put constant potential boundary condition on its surface, specify an arbitrary non zero electric charge in one of the vertices on the surface of the conductor (in fact, the charge will be distributed over the conductor's surface), and turn off all other field sources in the model. Once the problem is solved, go to the Postprocessor and take the value of electric potential somewhere on the surface of the conductor. The capacitance of the conductor can be obtained from the equation

C = q / U,

where q is the electric charge and U is the potential of the conductor.

To calculate mutual capacitance between two conductors put a charge on one conductor and measure electric potential on another. Constant potential boundary condition has to be applied to the surfaces of both conductors.

C12 = q1 / U2.