Differential transformer consists of 3 coils and a movable ferromagnetic core. Excitation is supplied to the central (primary) coil, and the output signal is measured on secondary coils.
How to calculate the output voltage as a function of core position?
Answer Typical applications Geometry
Given
Task
Solution
Results
Engineering question
Sweep the core position with LabelMover in an axisymmetric AC-magnetic model and record the differential output voltage at each position.
LVDT displacement sensors, inductive position sensors, linear motion transducers
Download
Simulation problem
Problem Type
Axisymmetric problem of AC magnetics.
Copper electrical conductivity g = 56 MS/m
Frequency f = 2 kHz
Excitation current I = 0.1 A
Calculate the output voltage as a function of core position.
Computations are automated using LabelMover tool.
Magnetic flux density distribution and the voltage vs. position dependency.