Differential transformer - QuickField simulation example

Differential transformer consists of 3 coils and a movable ferromagnetic core. Excitation is supplied to the central (primary) coil, and the output signal is measured on secondary coils.

Engineering question

How to find LVDT sensitivity?

Answer
Set up an axisymmetric QuickField AC Magnetics problem for an LVDT transformer and evaluate sensitivity from computed field results.

More questions →

Typical applications
LVDT displacement sensors, inductive position sensors, linear motion transducers

Differential transformer

Download

Simulation problem

Problem Type
Axisymmetric problem of AC magnetics.

Geometry
Differential transformer Differential transformer consists of 3 coils and a movable ferromagnetic core Core Left coil Right coil Excitation

Given
Copper electrical conductivity g = 56 MS/m
Frequency f = 2 kHz
Excitation current I = 0.1 A

Task
Calculate the output voltage as a function of core position.

Solution
Computations are automated using LabelMover tool.

Results
Magnetic flux density distribution and the voltage vs. position dependency.